Electric Current Transformer
![]() |
![]() General Electric Current Transformer 1001 FREE SHIPPING US $916.00
|
![]() General Electric 785 201 Current Transformer US $389.99
|
![]() GENERAL ELECTRIC CURRENT TRANSFORMER 753X20G3 NIB US $247.50
|
![]() GENERAL ELECTRIC CURRENT TRANSFORMER 754X20G3 NIB US $247.50
|
![]() GENERAL ELECTRIC CURRENT TRANSFORMER 753X20G5 NIB US $247.50
|
![]() GENERAL ELECTRIC CURRENT TRANSFORMER 761X20G4 NIB US $247.50
|
![]() GENERAL ELECTRIC CURRENT TRANSFORMER 693X71 NIB US $202.50
|
![]() GENERAL ELECTRIC NEUTRAL CURRENT TRANSFORMER TSRG201 USED US $202.50
|
![]() Electric Metering 8111SH 2500 Current Transformer US $179.99
|
![]() General Electric Current Transformer 750X33G303 36970 US $125.00
|
![]() General Electric Current Transformer 755 Ratio JKM 3 US $125.00
|
![]() DIVERSIFIED ELECTRIC CURRENT TRANSFORMER CT 25 5 US $120.00
|
![]() General Electric Current Transformer 755 Ratio JKC 3 US $85.00
|
![]() GENERAL ELECTRIC GE CURRENT TRANSFORMER 8005 120 801 US $75.00
|
![]() NEW General Electric 2005 Current Transformer 750X34G1 US $63.74
|
![]() GENERAL ELECTRIC TYPE JKM 3 CURRENT TRANSFORMER US $50.00
|
![]() General Electric Current Transformer 750X34G1 JCR 0 Ratio 2005 36973 US $49.99
|
![]() General Electric A C Amperes Current Transformer NOS US $49.99
|
![]() Midwest Electric 02 KVA 3CT11 Current Transformer TRA1999 US $19.99
|
![]() MIDWEST ELECTRIC 3CT115 USED CURRENT TRANSFORMER 3CT115 US $19.95
|
![]() Weschler Electric 2RL 500 Current Transformer NIB US $18.00
|
![]() GE General Electric Current Transformer 631X30 06KV US $17.00
|
![]() General Electric Current Transformer 2005 631X29 US $15.00
|
![]() 4 SETS FUJI ELECTRIC CURRENT TRANSFORMERS AC AMMETERS US $10.00
|
What are Transformer Designs?
An autotransformer has only a single winding, which is tapped at some point along the winding. Auto transformer is considered less costly, lighter, smaller and more efficient than a two-winding transformer of a similar rating. For three-phase power, three separate single-phase transformers can be used, or all three phases can be connected to a single polyphase transformer. The three primary windings are connected together and the three secondary windings are connected together.
Instrument transformers are divided into current transformers and voltage transformers. Current transformers are commonly used in electricity meters to facilitate the measurement of large currents which would be difficult to measure more directly. Current transformers are often constructed with a single primary turn either as an insulated cable passing through a toroidal core, or else as a bar to which circuit conductors is connected. Voltage transformers are used in the electricity supply industry to measure accurately the voltage being supplied. They are designed to present negligible load to the voltage being measured.
A pulse transformer is used to transmit rectangular electrical pulses. Small sized power versions are used in digital logic and telecommunications circuits, medium sized power versions are used in power-control circuits such as camera flash controllers. Special high voltage pulse transformers are also used to generate high power pulses for radar, particle accelerators or other pulsed power applications.
RF transformers are made from configurations of transmission line, bifilar or coaxial cable, wound around ferrite cores. This type of transformer is frequently used as an impedance matching balun to convert from 300 ohm balanced to 75 ohm unbalanced in FM receivers.
A resonant transformer operates at the resonant frequency of one or more of its coils. The resonant coil, usually the secondary, acts as an inductor, and are connected in series with a capacitor. If the primary coil is driven by a periodic source of alternating current, such as a square or sawtooth wave, each pulse of current helps to build up an oscillation in the secondary coil. The current got from this type of coil can be much larger than that from electrostatic machines such as the Van de Graaff generator and Wimshurst machine. They also run at a higher operating temperature than standard units.
The function of output transformer was to convert the low alternating current music signal into a useable high current/low voltage level for conversion by the loudspeakers. Certain large power transformers are used for electric arc furnaces used in steelmaking.
About the Author
Nisha is a Copywriter of electronic transformer. She written many articles in various topics.For more information visit:power transformer. contact she at malar.article@gmail.com
help with SCIENCE HOMEWORK?
1) a transformer changes. A) both the amperage and the voltage of an electric current. B) the voltage of an electric current. C) the amperage of an electric current. D)the type of an electric current
2) transformers can. A) increase voltage. B) decrease voltage. C) neither increase or decrease voltage. D) increase or decrease voltage.
1). A
2). D
Transformers can be either step-up or step-down. The ratio of output to input voltage is the same as the ratio of the number of coils in the out put to the number in the input.
And of course, as voltage changes, so does current - in the Opposited D.irection....................................
High current transformer 5000A 1,58Volt